Guardian Technologies EV9102 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 15
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
E-4 E-5
UV-C Light Bulb & Filter
Ultraviolet light technology, the same technology used in hospitals and commercial settings
for sanitizing, is capable of eradicating mircoorganisms, mold spores and viral contaminants
from the air.
It is recommended that you leave the Germ Guardian UV-C Air Sanitizer running continuously.
A replaceable 9-watt UV-C light bulb is guaranteed to last 8,000 hours - almost a full year of
continuous use. A lter that helps reduce odors is also in the product and should be replaced
once a year. Over time, with use, the 9-watt UV-C bulb will lose some intensity (about 15% at
9,000 hours), therefore it is suggested that the light bulb be replaced once every year. You will
know when to change the 9-watt light bulb when it continuously ickers or changes color. The
replacement bulb and lter come in one package.
To reorder bulb & lter pack EV9LB or EV9LBL, please call Customer Service 1.866.603.5900 or
go to www.germguardian.com.
Use of the Germ Guardian Unit
When the Germ Guardian is turned on you will see two rings of blue light that let you know it is
working. The Germ Guardian UV-C Room Air Sanitizer can process 1,380 cubic feet of air per hour
and is effective in almost any size room. Depending on dust conditions and build-up, you may need
to occasionally clean the bulb and cylinder with a soft, dry cloth. This product is safe for use around
children and pets, and is cool to the touch.
WARNING: Electrical Shock
UNDER NO CIRCUMSTANCES SHOULD YOU CLEAN THE BULB, BULB HOLDER OR
CYLINDER WITH WATER OR WET SOLUTIONS. THIS COULD CAUSE ELECTRICAL SHOCK.
Directions for Use
Plug unit into a 120V AC electrical outlet.1.
Switch the power button to the ON position. 2.
A small red light should light up on the switch.
Use the knob next to the power switch to 3.
adjust the fan speed. Turn the knob
clockwise for increased air ow.
For best results continuous operation 4.
is recommended.
NOTE: THE GERM GUARDIAN UNIT CONTAINS NO SERVICEABLE PARTS EXCEPT ITS
UV-C BULB AND FILTER. THE BULB AND FILTER MAY BE REMOVED FOR REPLACEMENT.
Replacing and Cleaning the UV-C Bulb & Filter
Turn off the unit and unplug it from 1.
the electrical outlet.
Using a small phillips head screwdriver, loosen and 2.
remove the phillips screw located at the top of the
unit, directly above the power cord.
Remove the top cap by lifting its side near the 3.
screw hole, then gently push the cap in the
opposite direction.
As the cap loosens, you may lift it off.4.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Electrical Shock
ALWAYS UNPLUG THE GERM GUARDIAN UNIT
FROM ELECTRICAL OUTLET WHEN SERVICING.
Page view 2
1 2 3 4 5 6 7 8 ... 14 15

Comments to this Manuals

No comments