Each input can respond to a contact closure or a contact opening, or
respond to both.
ANOnn
Set contact nn normally open
ANCnn
Set contact nn normally closed
Images transmitted on alarm
The action taken on detection of an alarm is for the DVST unit to store a point of alarm
image, dial the telephone number stored in dial menu number 0 and transmit the image.
The resolution of alarm images, and the screen mode in which they
are transmitted can be selected with the following command:
ATYPEn=
HI Selects a High resolution alarm image
LO Selects a Low resolution alarm image
The alarm settings are displayed in the view mode as follows, (type
VIEW <ENTER> and press a key until the following display appears)
Alarm Number Input Status Type Contacts
01: ALARM 01 On FULLHI N/O
02: ALARM 02 On FULLLO N/O
03: ALARM 03 On FULLHI N/C
04: ALARM 04 On FULLLO N/C
05: ALARM 05 Off
06: ALARM 06 Off
07: ALARM 07 On FULLHI N/O
08: ALARM 08 On FULLLO N/O
09: ALARM 09 On FULLHI N/O
10: ALARM 10 On FULLLO N/O
11: ALARM 11 On FULLHI N/O
12: ALARM 12 On FULLLO N/O
13: ALARM 13 On FULLHI N/O
14: ALARM 14 On FULLLO N/O
15: ALARM 15 On FULLHI N/O
16: ALARM 16 On FULLLO N/O
Page 50 Dedicated Micros Ltd
Alarms & Events DVST Installation Guide