Guardian Technologies , LLC Home Security System DVST User Manual Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
AOUT=
Set alarm outputs AUTO / MANUAL
(default is AUTO)
The two alarm contacts can be configured for automatic or manual
operation.
AUTO
In automatic mode relay 1 acts as a line indicator and closes whenever
the DVST is on line.
MANUAL
In manual mode the AUX1 key on the local unit controls relay 1 on the
remote unit, this works as a momentary contact. AUX2 on the local unit
controls relay 2, which works as a toggle on / off (latching) control.
ALMODE=
...Set Alarm operation mode
NOFRZ/OLNFRZ/ FRZALL/TRKLST
(default, OLNFRZ)
NOFRZ
No freeze mode - No frozen images are sent. If several alarms ocour
to trigger the machine to dial, one shot from each will be sent in quick
succession without any operator control. Any alarms present whilst on
line will be indicated on the receive unit display baseline.
OLNFRZ
Offline alarm freeze - Only freezes the first alarm image and then
transmits this image to the receiver. Subsequent alarms incoming
while the uniit is transmitting to a receiver are flagged on the baseline
but are not frozen, nor do they need to be acknowledged.
FRZALL
Freeze all alarm images - All alarm images are frozen. All must be
acknowledged by the receiving station before the alarm can be
cleared.
TRKLST
Track last alarm - No frozen images are sent. If several alarms ocour to
trigger the machine to dial, one shot from each alarm will be sent in
quick succession without any operator control, following an intruder.
Any alarms present whilst on line will be displayed full screen and un
frozen.
Dedicated Micros Ltd Page 51
DVST Installation Guide Alarms & Events
Page view 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 79 80

Comments to this Manuals

No comments