Guardian Technologies , LLC Home Security System DVST User Manual Page 48

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 47
AT&W<RET>
<ESC>
QUIT <RET>
These commands are entered using
Setup Mode on the DVST0200 unit via
a PC. Refer to Chapter para
The Citam is configured to operate on DVST.
X21
Cables required - 2x15 to 15 (Part No. AS-DVST-X21)
Dip switch settings can be used and should be set as follows:
Note: Switch 3 selects the sub address, if used
Step Instruction Remarks
1 Using the pull handle, remove the
circuit board module from the Citam
500
2 Adjust the dip switches as shown in
Figure 10
The Citam will nowperform a self test
On completion the dispaly will read
ISDN
3 Press the select key four times so
that the legend ‘CONF’ appears on
the display
4 Press the enter key once and it will
say ‘PRT1’, press the select key
twice it will say ‘TA, press the enter
key it will say ‘SHOW’
5 Press the hold select until the display
reads ‘CHNG’ remove your finger
from the select key and press the
enter key, ‘INDB’ will be displayed
6 Press theenter key, themessage will
be ‘ON’,use the select key to turn this
to ‘OFF’, then press the enter key
7 Hold the select key and press the
enter key, the display will return to
‘CONF’
This has turned off the in-band test
feature of the unit
8
At ‘CONF’ press the enter key, the
display will read ‘PRT1’ for port 1
Page 36 Dedicated Micros Ltd
Terminal Adapters DVST Installation Guide
Fig 6: ASCOM internal dip switch settings (X21)
Page view 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 79 80